SOME USEFUL INFORMATION FOR APPLICATORS


Estimating Cost of Material 

Calculation: Sq/Ft Coverage
Sq/Ft Coverage =1600 X (%Solids /100) X (%Transfer Efficiency/ 100) / Mil Thickness.
Example: Material is 40% Solids. Transfer Efficiency is 80% (typical of spray) and coating thickness reqd is 0.5 Mil.
Sq/Ft= 1600 X (.40) X (.80) / (0.5) = 1024 Sq/Ft

Calculation for Coating Thickness Conversion

Calculation: Thickness Conversion
1 Inch = 2.54 cm = 25.4 mm
.001 Inch = 1.0 mil = .025 mm = 25.4  micron

Calculation for Bake Temperature Conversion

Calculation: Temperature Conversion
deg F=(deg C X 1.8) +32
deg C=(deg F -32) X 0.555

Environmental

VOC
Volatile (evaporates) Organic (Carbon based) Compounds. 
Common VOC Exempted Materials Include:
Acetone, Methyl Acetate, p-Chlorobenzotrifluoride (Oxsol 100), Methylene Chloride, Perchloroethylene.

Photochemically Reactive Solvents
Refers to combinations of some solvents.
Common Solvents Includes 20% or more of: Toluene, Trichloroethylene

ODC
Ozone Depleting Compounds
Includes: 1,1,1 Trichloroethane

California Proposition 65
May Cause Cancer, Includes: Cadmium, Chromium, Nickel and Lead Compounds, Methylene Chloride, Perchloroethylene, Trichloroethylene
Reproductive Toxicity, Includes: Toluene 

AQMD
Rule 1107 Coating of Metal Parts and Products
(Note: Solid Film Lubricants are exempted)
Rule 1124 Aerospace Assembly and Component Manufacturing Operations.

Material Safety Data Sheet Information

MSDS General Info:
29CFR Dept of Labor / OSHA section 191-1200 - Hazardous Communication Standards/ Haz. Programs/ MSDS


40CFR EPA / Emergency Planning/ Right to Know/ CERCLA- Comprehensive Environment ResponseCompensation & Liability Act/ SARA- Superfund Amendment & Reauthorization Act


49CFR Dept of Transportation -Rules for Shipping / Transport Emergencies


CAS# -Chemical Abstract Service (American Chemical Society) - assigns unique ID # to chemicals


ACGIH (American Conference Govt. Industrial Hygenists): TLV- Threshold Limit Value (TLV-TWA-Allowable Time Weighted Ave/ 40 Hr week) (TLV-STEL- Short Term-15min) (TLV-C-Ceiling)


OSHA PEL: Permissible Exposure Limit


Flammable Flash Point < 100F, Combustible 100-200F
Explosive Limits, LEL (Lower) & UEL (Upper) -noted as a percentage (> or < to lean or rich to explode)
NFPA (National Fire Protection Assoc) & HMIS-Hazardous Materials ID System (National Paint & Coating Assoc) Ratings 0 to 3 for Health (Blue), Fire (Red), Reactivity (Yellow)


Carcinogen Lists: IARC (International Agency for Research on Cancer), NTP (Nat Toxicity Program), OSHA, Calif Prop 65




 

 

...


For More Information Contact:


Trans Chem Coatings 1811 S. Hope St. Los Angeles CA. 90015